Description
Introduction
The DLAB HiPette 1000-5000µL Micropipette USA brings American-standard engineering to laboratories across Bangladesh. Furthermore, DLAB designs this pipette to meet ISO 8655 international standards, so every measurement delivers consistent and trustworthy results. In addition, the 1000 µL to 5000 µL volume range makes this instrument a smart and flexible choice for many different lab tasks.
Specifications
| Brand | DLAB |
| Origin | USA |
| Model | HiPette |
| Volume Range | 1000 – 5000 µL |
| Volume Increment | 100 µL |
| Accuracy (at 5000 µL) | ±0.6% |
| Precision (CV%) | ≤0.2% |
| Channels | Single Channel |
| Tip Ejection | One-touch tip ejector |
| Autoclavable | Yes – lower part at 121°C |
| Calibration | User-adjustable in-house calibration |
| Volume Display | Rotating digital display window |
| Body Material | Medical grade polypropylene |
| Ergonomics | Lightweight, low plunger force design |
| Color Coding | Yes – volume-specific color identification |
| Compatible Tips | DLAB 5 mL pipette tips |
| Warranty | 2 Years |
| Certifications | ISO 8655, CE Certified |
| Standards Compliance | Meets USA and international volumetric accuracy standards |
Frequently Asked Questions
Product and Technical Questions
Q1: What does ‘USA’ mean in the DLAB HiPette 1000-5000µL Micropipette USA?
A: The ‘USA’ label indicates that DLAB designs and engineers this pipette to meet American laboratory standards. Therefore, buyers in Bangladesh receive a product that matches the quality and accuracy requirements of top USA research institutions.
Q2: What is the volume range of the DLAB HiPette 1000-5000µL Micropipette USA?
A: The pipette covers 1000 µL to 5000 µL with 100 µL increments. Therefore, it suits a wide range of liquid transfer tasks in research and clinical labs across Bangladesh.
Q3: Can laboratory staff autoclave this pipette for sterile use?
A: Yes. Users can autoclave the lower section at 121°C. As a result, the pipette stays sterile and safe for sensitive applications such as cell culture and clinical sample handling.
Q4: Which tips work with the DLAB HiPette 1000-5000µL Micropipette USA?
A: The pipette works best with DLAB 5 mL pipette tips. Moreover, compatible universal tips that fit the tip cone securely also work well for everyday lab tasks.
Calibration, Warranty, and Purchase Questions
Q5: Can lab staff calibrate the DLAB HiPette USA without an external service center?
Who Uses This
| User Type | How They Use It |
| Research Scientists | Measure and transfer liquids with high accuracy in daily experiments |
| Medical Lab Technicians | Process diagnostic samples quickly and safely |
| Pharmaceutical QC Teams | Test drug compounds and control product quality |
| University Students & Faculty | Complete academic research and practical lab training |
| Biotechnology Companies | Run bioassays, cell cultures, and enzyme studies |
| Food Testing Laboratories | Prepare and aliquot food samples for analysis |
| Environmental Testing Labs | Handle water, soil, and air samples with precision |
Key Features
Volume Range and Accuracy
- Wide Volume Range: Covers 1000 µL to 5000 µL with 100 µL increments, so labs handle many liquid transfer tasks with one pipette
- High Accuracy: Achieves ±0.6% accuracy at 5000 µL and meets ISO 8655 USA and international standards, therefore ensuring reliable results every time
- Rotating Digital Display Window: Shows the volume setting clearly, so lab staff read and adjust volumes quickly at any time
Comfort and Daily Usability
- Low Plunger Force: Reduces hand and wrist fatigue during long sessions, which helps lab staff maintain consistent performance throughout the working day
- One-Touch Tip Ejector: Releases tips cleanly with a single press, consequently removing the risk of cross-contamination between samples
- Color-Coded Volume Identification: Uses a distinct color per volume range, so lab staff quickly pick the right pipette from the bench without confusion
Applications
Life Sciences and Research
- Molecular Biology: Prepares PCR master mixes, quantifies DNA and RNA, and loads agarose gels with precise and repeatable volumes
- Biochemistry: Runs enzyme assays, quantifies proteins, and prepares buffer solutions with accurate and consistent delivery
- Microbiology: Transfers liquid cultures, prepares growth media, and supports cell counting procedures in research environments
Clinical, Industrial, and Environmental Use
- Clinical and Diagnostic Laboratories: Processes patient samples, dispenses reagents, and sets up ELISA plates quickly and efficiently
Why Buy from astzbd
- Bangladesh’s Trusted Scientific Supplier — serving labs nationwide
- 100% Genuine DLAB Products — no counterfeit, no compromise
- Fast Delivery Across Bangladesh — Dhaka and all districts
- After-Sales Support — technical assistance and calibration guidance
- Competitive Pricing — best value for lab-grade equipment
- Secure Packaging — products arrive safely and ready to use
- Trusted by Hospitals, Universities & Research Institutes across Bangladesh
ADVANCE SCIENCE & TECHNOLOGY ZONE
E-mail: astzbd@gmail.com, Website: WWW.ASTZBD.COM
Cell: +88 01329100999
Reviews
There are no reviews yet.