Description
Soft Case Model
- 3-Pole and 2-Pole Earth Resistance
- The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes
- Dust and drip proof (designed to IEC 60529 IP54)
- Earth resistance value can be read directly from the scale
- Designed to meet IEC 61010-1 safety standard
- Capable of measuring earth voltage
- Small and lightweight. Shock resistant new case material
- 2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test
Earth resistance measurement |
20Ω | 200Ω | 2000Ω | |
---|---|---|---|---|
Measuring range | 0.00 – 1999Ω | |||
Display range | 0.00 – 19.99Ω | 0.0 – 199.9Ω | 0 – 1999Ω | |
Accuracy | ±2%rdg±0.1 Ω | ±2%rdg±3dgt | ||
Earth voltage measurement | ||||
Measuring range | 0 – 200 V AC (50,60Hz) | |||
Display range | 0.0 – 199.9 V | |||
Accuracy | ±1%rdg±4dgt | |||
Overload protection | Earth resistance : 280V AC (10 seconds) Earth voltage : 300V AC (1 minute) |
|||
Applicable standards | IEC 61010-1 CAT Ⅲ300 V Pollution degree 2 IEC 61010-2-030, IEC 61557-1,5, IEC 60529 (IP54) |
|||
Power source | R6(AA)(1.5V) × 6 | |||
Dimension | 105(L) × 158(W) × 70(D) mm (including case lid) | |||
Weight | Approx. 550g (including batteries and case lid) |