Biobase Ducted Fume Hood FH1500X

490,000.00৳ 

Key Features & Capabilities

  • Effective Fume Extraction: Helps remove hazardous fumes, vapors, and gases from the laboratory workspace.

  • Enhanced Operator Safety: Helps reduce exposure to harmful chemical vapors during laboratory procedures.

  • Adjustable Airflow: Features 9-level airspeed adjustment for different laboratory requirements.

  • Motorized Front Window: 5 mm UV-resistant toughened glass with motorized height adjustment.

  • UV Sterilization Lamp: Supports surface and workspace decontamination when used appropriately.

  • Chemical-Resistant Worktop: Phenolic resin work surface designed to resist chemicals.

  • Microprocessor Control: LED display shows filter working time for convenient monitoring.

  • Filter-Time Alarm: Provides an alarm when the filter working time reaches 3,500 hours.

  • Ergonomic Design: Angled front panel supports a more comfortable working posture.

  • Improved Airflow Distribution: Rear air compensation helps reduce turbulence inside the working area.

  • Clear Side Windows: Transparent panels improve visibility inside the cabinet.

  • Integrated Utility Connections: Standard accessories include water and gas taps, a sink, and waterproof electrical sockets.

 

Brand: Biobase | Model: FH1500X | Capacity: 1500mm | Country of Origin: China

Description

Introduction Biobase ducted fume hood

The ducted fume hood FH1500X from Biobase protects lab staff from toxic vapors, acid fumes and harmful gases. It pulls contaminated air through the front opening and sends it out through an exhaust duct. Moreover, a built-in centrifugal blower keeps the airflow steady across nine speed levels. The 1500 mm width gives operators generous room for large setups and team work. A UV lamp sterilizes the work area after each session. In addition, the microprocessor control system shows the filter working time on an LED display. The porcelain PP body resists acid, alkali and corrosion. Operators also benefit from the 8° sloped front, which supports a comfortable working posture. Therefore, the unit suits busy chemistry, pharmaceutical and research labs.

Technical Specifications biobase fume hood

Parameter Detail
Brand Biobase
Model FH1500X
Type Ducted fume hood
Exterior Size (W x D x H) 1500 x 840 x 2150 mm
Internal Size (W x D x H) 1380 x 730 x 745 mm
Work Surface Height 750 mm
Maximum Opening 520 mm
Blower Built-in centrifugal blower
Air Speed Control 9 adjustable levels
Air Velocity 0.3-0.8 m/s
System Exhaust Volume 990 m³/h
Noise Level ≤68 dB
LED Lamp 16 W x 1
UV Lamp Yes, for sterilization
Front Window Motorized glass window
Side Windows Transparent glass
Front Design 8° slope, ergonomic
Control System Microprocessor with LED display
Filter Alarm Alerts at 3500 working hours
Power Failure Protection Memory function
Air Compensation Back side air compensation
Body Material Porcelain PP, resistant to acid and alkali
Country of Origin China

 

Key Features laboratory fume hood

  1. The UV lamp sterilizes the work area after each use.
  2. The motorized front glass window opens and closes with a simple control.
  3. Operators choose from 9 air speed levels to match each task.
  4. The alarm warns users when the filter reaches 3500 working hours.
  5. The memory function restores your settings after a power failure.
  6. Back side air compensation reduces turbulence in the work area.
  7. The 8° sloped front lets operators work with less fatigue.
  8. The microprocessor control system shows the filter working time on an LED display.
  9. Moreover, the porcelain PP body resists weak acid, alkali and corrosion.
  10. The wide 1380 mm interior gives you ample room for equipment and samples.

Who Uses This chemical fume hood

  1. Chemistry laboratories in schools and universities
  2. Pharmaceutical quality control teams
  3. Research and development centers
  4. Hospital and diagnostic laboratories
  5. Environmental testing laboratories
  6. Industrial quality control departments
  7. Textile and chemical factory labs

Applications fume hood price in Bangladesh

  1. Handling strong acids and alkalis safely
  2. Working with volatile solvents and corrosive substances
  3. Preparing samples that release toxic fumes or vapors
  4. Running general chemical experiments in teaching labs
  5. Testing in pharmaceutical and food laboratories
  6. Handling materials with potentially hazardous factors
  7. Protecting the lab air when you install a suitable filter

Frequently Asked Questions ducted fume hood

  1. What does a ducted fume hood do?
    A ducted fume hood pulls contaminated air away from the operator and sends it outside through an exhaust duct. As a result, it keeps toxic fumes out of the breathing zone.
  2. What size is the FH1500X?
    The FH1500X measures 1500 x 840 x 2150 mm on the outside. The internal work area measures 1380 x 730 x 745 mm.
  3. How many air speed levels does it offer?
    The blower offers 9 adjustable speed levels. Operators set the airflow between 0.3 and 0.8 m/s.
  4. What exhaust volume does the FH1500X deliver?
    The system moves 990 m³/h of air.
  5. What happens during a power failure?
    The memory function saves your settings, so the hood resumes normal work when power returns.
  6. How loud is the FH1500X?
    The noise level stays at or below 68 dB.
  7. Where does this hood come from?
    Biobase manufactures it in China.

Why Buy From astzbd biobase fume hood

  1. Astzbd supplies genuine Biobase laboratory equipment.
  2. Our team helps you choose the right model for your lab.
  3. We deliver across Bangladesh with careful packaging.
  4. Our support team answers your installation and usage questions.
  5. You receive competitive pricing and dependable after-sales service.