Description
Introduction LUTRON AM-4210 Anemometer
The LUTRON AM-4210 Anemometer stands as one of the most versatile handheld air velocity instruments available in Bangladesh today. Engineers, HVAC technicians, and environmental researchers who need reliable wind speed data alongside precise temperature readings turn to this instrument for its dual-function capability. The LUTRON AM-4210 Anemometer combines a low-friction ball-bearing vane sensor with a Type K/J thermocouple input, delivering simultaneous readings on a large dual LCD display.
Key Features LUTRON AM-4210 Anemometer
- Measures air velocity in five units: m/s, km/h, ft/min, knots, and mile/h
- Dual-function LCD (44 mm × 29 mm) shows air velocity and temperature simultaneously
- Accepts Type K thermocouple probes (range: −100 to 1300 °C) and Type J probes (range: −100 to 1200 °C)
- 1,600-point built-in data logger with selectable auto sampling intervals (2, 5, 10, 30, 60, 600, 1800, 3600 seconds)
- Records maximum and minimum readings with recall function
- RS-232 PC serial interface for data transfer to computer
- Low-friction ball-bearing vane probe ensures accuracy at both high and low velocities
- Data Hold function freezes the live reading on screen
- Auto power-off or manual power-off selectable by user
- Compact pocket-size housing (135 × 60 × 33 mm) weighing only 322 g
- Built-in low battery indicator
- Microprocessor LSI circuit provides linear compensation across full range
- Optional RS-232 cable, USB cable, data-acquisition software, and carrying case
- Operates on DC 9V battery (006P) or optional DC 9V adapter
- ISO-9001, CE, and IEC1010 certified — made in Taiwan
Specifications LUTRON AM-4210 Anemometer
| Unit | Range | Resolution | Accuracy |
| m/s | 0.4 – 25.0 m/s | 0.1 m/s | ± (2% + 1d) |
| km/h | 1.4 – 90.0 km/h | 0.1 km/h | ± (2% + 1d) |
| mile/h | 0.9 – 55.9 mile/h | 0.1 mile/h | ± (2% + 1d) |
| knots | 0.8 – 48.6 knots | 0.1 knots | ± (2% + 1d) |
| ft/min | 80 – 4930 ft/min | 1 ft/min | ± (2% + 20 ft/min) |
| Parameter | Range | Resolution | Accuracy |
| Temperature (°C) | 0 to 50 °C | 0.1 °C | ±0.8 °C |
| Temperature (°F) | 32 to 122 °F | 0.1 °F | ±1.5 °F |
| Range | Values | Resolution | Accuracy |
| High °C | -50.0 to 1300.0 °C | 0.1 °C | ±(0.4% + 0.8 °C) |
| Low °C | -50.1 to -199.9 °C | 0.1 °C | ±(0.4% + 1 °C) |
| High °F | -58.0 to 2372.0 °F | 0.1 °F | ±(0.4% + 1.5 °F) |
| Low °F | -58.1 to -327.8 °F | 0.1 °F | ±(0.4% + 1.8 °F) |
| Range | Values | Resolution | Accuracy |
| High °C | -100.0 to 1100.0 °C | 0.1 °C | ±(0.4% + 0.8 °C) |
| Low °C | -50.1 to -199.9 °C | 0.1 °C | ±(0.4% + 1 °C) |
| High °F | -58.0 to 2012.0 °F | 0.1 °F | ±(0.4% + 1.5 °F) |
| Low °F | -58.1 to -327.8 °F | 0.1 °F | ±(0.4% + 1.8 °F) |
| Parameter | Value |
| Model | AM-4210 |
| Brand / Origin | Lutron Electronic Enterprise, Taiwan |
| Certifications | ISO-9001, CE, IEC1010 |
| Circuit | Custom one-chip microprocessor LSI |
| Display | Dual LCD, 44 mm × 29 mm |
| Probe Type | Separate vane probe + Type K/J thermocouple input |
| Data Logger Capacity | 1,600-point maximum |
| Sampling Interval (Auto) | 2, 5, 10, 30, 60, 600, 1800, 3600 seconds |
| Sampling Time (Display) | Approx. 1 second |
| Data Output | RS-232 PC serial interface |
| Power Supply | DC 9V battery (006P) or DC 9V adapter (optional) |
| Power Current — Anemometer | Approx. DC 10.5 mA |
| Power Current — Thermocouple | Approx. DC 6.8 mA |
| Operating Temperature | 0 to 50 °C |
| Operating Humidity | Less than 80% RH |
| Dimensions (Meter) | 135 × 60 × 33 mm (5.3 × 2.4 × 1.3 inch) |
| Probe Dimensions | Round, 72 mm diameter |
| Weight | 322 g / 0.71 lb |
| Auto Power Off | Yes (selectable manual or auto) |
| Data Hold | Yes |
| Max/Min Recall | Yes |
| Low Battery Indicator | Built-in |
Applications LUTRON AM-4210 Anemometer
- HVAC system commissioning and air balance verification in commercial and industrial buildings
- Air-conditioning and ventilation duct velocity profiling
- Wind speed monitoring at meteorological stations and research sites
- Cleanroom and laminar-flow cabinet air-change rate verification
- Industrial furnace and kiln temperature measurement with Type K thermocouple
- Food processing and cold-storage temperature monitoring
- Pharmaceutical and biotechnology laboratory environmental checks
- University and research institution fluid dynamics experiments
- Textile and garment factory air-flow balance audits
- Occupational health and safety indoor air quality surveys
- Fire and safety engineering smoke-exhaust system testing
- Marine vessel ventilation system inspection
Who Uses This LUTRON AM-4210 Anemometer
- HVAC engineers and mechanical engineers commissioning air handling units
- Building services consultants conducting energy audits
- Environmental health officers measuring workplace air quality
- Quality control technicians in pharmaceutical and food factories
- University professors and students conducting laboratory experiments
- Fire safety engineers testing smoke extraction systems
- Meteorology department staff at weather monitoring stations
- Research and development engineers requiring multi-point data logging
- Industrial maintenance technicians monitoring furnace temperatures
- Government inspectors checking factory ventilation compliance
Frequently Asked Questions (FAQ)
Q1: What air velocity units does the LUTRON AM-4210 Anemometer measure?
The LUTRON AM-4210 Anemometer measures air velocity in five units: meters per second (m/s), kilometers per hour (km/h), feet per minute (ft/min), knots, and miles per hour (mile/h). Users switch between units using the panel button.
Q2: Can the AM-4210 measure temperature?
Yes. The meter includes a built-in precision thermistor for ambient temperature (0 to 50 °C). Additionally, it accepts external Type K probes (up to 1300 °C) or Type J probes (up to 1200 °C) via the standard two-pin thermocouple socket.
Q3: How many data points does the data logger store?
The built-in data logger stores a maximum of 1,600 data points. Users set automatic sampling intervals at 2, 5, 10, 30, 60, 600, 1800, or 3600 seconds, or they save one point manually per button press.
Q4: Does the LUTRON AM-4210 connect to a computer?
Yes. The meter has an RS-232 serial interface. Users connect it to a PC using the optional UPCB-02 RS-232 cable or the USB-01 USB cable. The optional SW-DL2005 software downloads logged data, and SW-U801-WIN provides live data acquisition with chart and report functions LUTRON AM-4210 Anemometer .
Q5: What battery does the AM-4210 use?
The meter runs on a standard 006P DC 9V battery (alkaline or heavy-duty type). LUTRON AM-4210 Anemometer It also accepts a DC 9V adapter (sold separately) for continuous mains-powered operation.
Q6: Is the LUTRON AM-4210 available in Bangladesh?
Yes. ASTZ Bangladesh stocks the LUTRON AM-4210 Anemometer at its Dhaka showroom. Customers throughout LUTRON AM-4210 Anemometer Bangladesh can order by calling +880 1329-100999 or emailing astzbd@gmail.com.
Q7: What certifications does this instrument hold?
The LUTRON AM-4210 Anemometer carries ISO-9001 quality management, CE European conformity, and IEC1010 electrical safety certifications. LUTRON AM-4210 Anemometer Electronic Enterprise manufactures it in Taiwan under these internationally recognised standards.
Q8: What accessories are available for the AM-4210?
Available optional accessories include: Type K thermocouple probes TP-01, TP-02A, TP-03, TP-04; RS-232 cable UPCB-02; USB cable USB-01; data logger software SW-DL2005; data acquisition software SW-U801-WIN; soft carrying case CA-05A; hard carrying case CA-06; and DC 9V AC/DC power adapter.
Q9: What is the accuracy of the air velocity measurement?
For m/s, km/h, mile/h, and knots the accuracy is ±(2% + 1 digit). For ft/min the accuracy is ±(2% + 20 ft/min). These values apply at the reference temperature of 23 ± 5 °C.
Q10: How large and heavy is the AM-4210?
The meter body measures 135 × 60 × 33 mm and weighs 322 g (0.71 lb). Its pocket-size form factor makes it easy to carry during fieldwork. The separate vane probe has a 72 mm round sensor head.
Why Buy from ASTZ Bangladesh LUTRON AM-4210 Anemometer
- ASTZ (Advance Science & Technology Zone) stocks genuine Lutron instruments imported directly from Taiwan — customers receive factory-authentic meters with full specifications.
- ASTZ provides full after-sales technical support from its Dhaka showroom at 1st Floor, Shop #13, Kader Tropical, 10 Shahid Nazrul Islam Road, Hatkhola, Tikatoly, Dhaka-1203.
- Expert sales staff assist customers in selecting the correct thermocouple probe type (K or J) and optional accessories for their specific application.
- ASTZ ships instruments to customers throughout Bangladesh, including Dhaka, Chittagong, Sylhet, Rajshahi, and Khulna divisions.
- Customers can contact ASTZ at +880 1329-100999 or +880 1329-100998 or by email at astzbd@gmail.com for quotations and technical guidance.
- ASTZ stocks optional accessories including UPCB-02 RS-232 cable, USB-01 cable, SW-DL2005 data logger software, SW-U801-WIN data acquisition software, and Type K thermocouple probes.
- The company serves leading national institutions including pharmaceutical companies, defence installations, and university research laboratories across Bangladesh.




Reviews
There are no reviews yet.