Lutron BCT-4320SD Benchtop Conductivity Meter with SD Card Data Logger

10.00৳ 

  • The Lutron BCT-4320SD Benchtop Conductivity Meter is a multi-function professional instrument that measures conductivity, TDS, hardness, resistivity, and salt from a single probe. It features a built-in SD card real-time data logger that records measurements with full time stamps directly to Excel — no software installation required. The meter includes automatic temperature compensation (ATC), RS232/USB PC interface, a green-backlit LCD, and the CDPB-04 Pt glass electrode. ISO-9001, CE, and IEC1010 certified. Ideal for laboratories, water treatment, food processing, and quality control applications in Bangladesh.
  • Brand: Lutron I Model: BCT-4320SD I Parameter: Conductivity, TDS, Salt, Temperature I Type: bench-top I Country of origin: Taiwan

Description

Introduction Lutron BCT-4320SD Benchtop Conductivity Meter 

The Lutron BCT-4320SD Bench-top Conductivity Meter stands as one of the most advanced multi-parameter water quality instruments available for laboratory and industrial professionals in Bangladesh today. The Lutron BCT-4320SD Bench-top Conductivity Meter delivers precise measurement of Conductivity, TDS (Total Dissolved Solids), Salt, and Temperature in a single, easy-to-operate bench-top unit equipped with a real-time SD card data logging system. Professionals across Bangladesh choose the Lutron BCT-4320SD Bench-top Conductivity Meter because it eliminates the need for additional software when transferring data. Users simply insert the SD card into a computer and open all recorded readings directly in Microsoft Excel. This process saves time, reduces errors, and keeps water quality monitoring smooth and efficient

Specifications Lutron BCT-4320SD Benchtop Conductivity Meter 

Parameter Details
Model BCT-4320SD
Brand Lutron Electronics Co., Ltd. — Taiwan
Type Benchtop Conductivity / TDS / Salt / Temperature Meter with SD Card Data Logger
Measurement Functions Conductivity (uS, mS), TDS (PPM), Salt (% Weight), Temperature (C / F)
Conductivity Ranges 20 uS / 200 uS / 2 mS / 20 mS / 200 mS — Auto Range
TDS Measurement Derived from conductivity reading (PPM)
Salt Measurement 0 to 12% salt (% by weight)
Temperature Range 0 degrees C to 60 degrees C / 32 degrees F to 140 degrees F
Temperature Resolution 0.1 degrees C / 0.1 degrees F
Temperature Accuracy +/-0.8 degrees C / +/-1.5 degrees F at 23 +/- 5 degrees C
Temp. Compensation (ATC) Automatic from 0 to 60 degrees C; coefficient adjustable 0 to 5.0% per degree C (default: 2.0%/C)
Display LCD, 52 mm x 38 mm, green backlight (ON/OFF switchable)
Circuit Custom one-chip microprocessor LSI circuit
SD Card Capacity 1 GB to 16 GB SD memory card
Datalogger — Auto Mode Sampling time: 1 second to 8 hours 59 minutes 59 seconds
Datalogger — Manual Mode Press button once to save one data point; supports up to 99 position tags
Data Output Format Direct Excel file via SD card — no PC software installation required
Data Timestamp Year / Month / Date / Hour / Minute / Second
PC Interface RS-232 and USB computer interface
Data Hold Yes — holds current reading on screen
Max / Min Recording Yes — tracks maximum and minimum values per session
Power Supply DC 1.5V (UM-3, AA) x 8 batteries OR optional DC 9V adapter
Auto Power Off Selectable — auto or manual power-off mode
Beep Function Yes — ON/OFF selectable from settings menu
Advanced Settings SD card format, clock/calendar, sampling time, power management, beep, decimal point, temp unit, temp coefficient
Operating Temperature 0 degrees C to 50 degrees C
Country of Origin Taiwan
Warranty As per supplier terms — contact ASTZ for details

Applications Lutron BCT-4320SD Benchtop Conductivity Meter 

  • Water treatment plants and municipal water supply quality monitoring across Bangladesh
  • Industrial wastewater monitoring and environmental compliance verification
  • Food and beverage processing — monitoring purity of process water and ingredient solutions
  • Aquaculture and fish hatcheries — maintaining optimal water conductivity for healthy fish production
  • Pharmaceutical and chemical laboratories — verifying solution quality and consistency
  • Boiler feed water and cooling water quality management
  • University and college research — water quality experiments with traceable logged data
  • Power generation plants — demineralized and treated water circuit monitoring
  • Textile and garment factories — process water quality control
  • Photography and printing industries — solution concentration measurement
  • Pulp and paper manufacturing — process water analysis
  • Electroplating industries — monitoring electrolyte concentration levels

Who Uses This Product Lutron BCT-4320SD Benchtop Conductivity Meter 

  • Laboratory technicians and chemists who need reliable multi-parameter water quality data with traceable records for compliance reporting
  • Quality control managers in food, beverage, and pharmaceutical companies who track water purity consistently across production shifts
  • Environmental engineers and water treatment professionals who require logged data for regulatory compliance documentation
  • University and college researchers who conduct water quality studies and need accurate, time-stamped data for academic work
  • Fish farm and aquaculture operators who monitor water conductivity to maintain healthy environments for livestock
  • Industrial plant operators who require continuous or scheduled data logging without manual intervention
  • Government testing laboratories and public health agencies that measure drinking water and wastewater quality for safety assurance Lutron BCT-4320SD Benchtop Conductivity Meter
  • Frequently Asked Questions (FAQ) Lutron BCT-4320SD Benchtop Conductivity Meter 

    Q: What does the Lutron BCT-4320SD Benchtop Conductivity Meter measure?

    A: The Lutron BCT-4320SD measures Conductivity (uS and mS), TDS (Total Dissolved Solids in PPM), Salt (% by weight), and Temperature (degrees C or F) — all from a single benchtop unit Lutron BCT-4320SD Benchtop Conductivity Meter.

    Q: Does the BCT-4320SD require special software to read logged data?

    A: No. The BCT-4320SD saves all data directly to an SD card in Excel-compatible format. Users remove the SD card, plug it into a computer, and open the file in Microsoft Excel immediately without installing any additional software.

    Q: What SD card size does the BCT-4320SD support?

    A: The meter accepts SD memory cards with a capacity of 1 GB to 16 GB.

    Q: Can users set the sampling interval for the data logger?

    A: Yes. In auto mode, users configure the sampling interval from 1 second up to 8 hours 59 minutes 59 seconds. In manual mode, pressing the logger button once saves a single data point at the current moment.

    Q: Does the BCT-4320SD compensate for temperature changes automatically?

    A: Yes. The meter features Automatic Temperature Compensation (ATC) across 0 degrees C to 60 degrees C. The temperature coefficient is adjustable between 0 and 5.0% per degree C, with a factory default of 2.0% per degree C.

    Q: What power source does the BCT-4320SD use?

    A: The meter operates on 8 AA (UM-3, 1.5V) batteries or an optional DC 9V adapter. The adapter option suits continuous benchtop operation without the need to replace batteries Lutron BCT-4320SD Benchtop Conductivity Meter.

    Q: Is the BCT-4320SD suitable for use outside the laboratory?

    A: While the BCT-4320SD is primarily a benchtop meter, battery operation allows users to carry it for multi-location field measurements. The manual data logger supports up to 99 position tags for organized multi-point data collection in the field Lutron BCT-4320SD Benchtop Conductivity Meter.

Why Buy from astz Lutron BCT-4320SD Benchtop Conductivity Meter 

  • ASTZ supplies genuine Lutron instruments through authorized channels, ensuring customers receive authentic products that meet full manufacturer specifications.
  • The ASTZ team provides professional pre-sales consultation to help buyers select the right instrument for their specific application and budget requirements.
  • ASTZ offers after-sales technical support, including guidance on setup, calibration, and day-to-day operation of the Lutron BCT-4320SD Benchtop Conductivity Meter.
  • Fast delivery across Bangladesh, including Dhaka, Chittagong, Sylhet, Rajshahi, and other major cities, ensures customers receive orders without unnecessary delays.
  • ASTZ maintains a wide inventory of Lutron instruments and accessories, allowing customers to source all measurement equipment needs from a single trusted supplier.
  • Competitive pricing and transparent billing make ASTZ a cost-effective choice for laboratories, industries, and educational institutions throughout Bangladesh.
  • ASTZ holds a proven track record of serving research institutions, industrial clients, and government bodies across Bangladesh with dependable measurement solutions.

Reviews

There are no reviews yet.

Be the first to review “Lutron BCT-4320SD Benchtop Conductivity Meter with SD Card Data Logger”