Description
Introduction
The Lutron BCT-4320SD Bench-top Conductivity Meter stands as one of the most advanced multi-parameter water quality instruments available for laboratory and industrial professionals in Bangladesh today. The Lutron BCT-4320SD Bench-top Conductivity Meter delivers precise measurement of Conductivity, TDS (Total Dissolved Solids), Salt, and Temperature in a single, easy-to-operate bench-top unit equipped with a real-time SD card data logging system.
Professionals across Bangladesh choose the Lutron BCT-4320SD Bench-top Conductivity Meter because it eliminates the need for additional software when transferring data. Users simply insert the SD card into a computer and open all recorded readings directly in Microsoft Excel. This process saves time, reduces errors, and keeps water quality monitoring smooth and efficient.
Specifications
| Parameter | Details |
| Model | BCT-4320SD |
| Brand | Lutron Electronics Co., Ltd. — Taiwan |
| Type | Benchtop Conductivity / TDS / Salt / Temperature Meter with SD Card Data Logger |
| Measurement Functions | Conductivity (uS, mS), TDS (PPM), Salt (% Weight), Temperature (C / F) |
| Conductivity Ranges | 20 uS / 200 uS / 2 mS / 20 mS / 200 mS — Auto Range |
| TDS Measurement | Derived from conductivity reading (PPM) |
| Salt Measurement | 0 to 12% salt (% by weight) |
| Temperature Range | 0 degrees C to 60 degrees C / 32 degrees F to 140 degrees F |
| Temperature Resolution | 0.1 degrees C / 0.1 degrees F |
| Temperature Accuracy | +/-0.8 degrees C / +/-1.5 degrees F at 23 +/- 5 degrees C |
| Temp. Compensation (ATC) | Automatic from 0 to 60 degrees C; coefficient adjustable 0 to 5.0% per degree C (default: 2.0%/C) |
| Display | LCD, 52 mm x 38 mm, green backlight (ON/OFF switchable) |
| Circuit | Custom one-chip microprocessor LSI circuit |
| SD Card Capacity | 1 GB to 16 GB SD memory card |
| Datalogger — Auto Mode | Sampling time: 1 second to 8 hours 59 minutes 59 seconds |
| Datalogger — Manual Mode | Press button once to save one data point; supports up to 99 position tags |
| Data Output Format | Direct Excel file via SD card — no PC software installation required |
| Data Timestamp | Year / Month / Date / Hour / Minute / Second |
| PC Interface | RS-232 and USB computer interface |
| Data Hold | Yes — holds current reading on screen |
| Max / Min Recording | Yes — tracks maximum and minimum values per session |
| Power Supply | DC 1.5V (UM-3, AA) x 8 batteries OR optional DC 9V adapter |
| Auto Power Off | Selectable — auto or manual power-off mode |
| Beep Function | Yes — ON/OFF selectable from settings menu |
| Advanced Settings | SD card format, clock/calendar, sampling time, power management, beep, decimal point, temp unit, temp coefficient |
| Operating Temperature | 0 degrees C to 50 degrees C |
| Country of Origin | Taiwan |
| Warranty | As per supplier terms — contact ASTZ for details |
Applications
- Water treatment plants and municipal water supply quality monitoring across Bangladesh
- Industrial wastewater monitoring and environmental compliance verification
- Food and beverage processing — monitoring purity of process water and ingredient solutions
- Aquaculture and fish hatcheries — maintaining optimal water conductivity for healthy fish production
- Pharmaceutical and chemical laboratories — verifying solution quality and consistency
- Boiler feed water and cooling water quality management
- University and college research — water quality experiments with traceable logged data
- Power generation plants — demineralized and treated water circuit monitoring
- Textile and garment factories — process water quality control
- Photography and printing industries — solution concentration measurement
- Pulp and paper manufacturing — process water analysis
- Electroplating industries — monitoring electrolyte concentration levels
Who Uses This Product
- Laboratory technicians and chemists who need reliable multi-parameter water quality data with traceable records for compliance reporting
- Quality control managers in food, beverage, and pharmaceutical companies who track water purity consistently across production shifts
- Environmental engineers and water treatment professionals who require logged data for regulatory compliance documentation
- University and college researchers who conduct water quality studies and need accurate, time-stamped data for academic work
- Fish farm and aquaculture operators who monitor water conductivity to maintain healthy environments for livestock
- Industrial plant operators who require continuous or scheduled data logging without manual intervention
- Government testing laboratories and public health agencies that measure drinking water and wastewater quality for safety assurance
Why Buy from astz
- ASTZ supplies genuine Lutron instruments through authorized channels, ensuring customers receive authentic products that meet full manufacturer specifications.
- The ASTZ team provides professional pre-sales consultation to help buyers select the right instrument for their specific application and budget requirements.
- ASTZ offers after-sales technical support, including guidance on setup, calibration, and day-to-day operation of the Lutron BCT-4320SD Benchtop Conductivity Meter.
- Fast delivery across Bangladesh, including Dhaka, Chittagong, Sylhet, Rajshahi, and other major cities, ensures customers receive orders without unnecessary delays.
- ASTZ maintains a wide inventory of Lutron instruments and accessories, allowing customers to source all measurement equipment needs from a single trusted supplier.
- Competitive pricing and transparent billing make ASTZ a cost-effective choice for laboratories, industries, and educational institutions throughout Bangladesh.
- ASTZ holds a proven track record of serving research institutions, industrial clients, and government bodies across Bangladesh with dependable measurement solutions.
Frequently Asked Questions (FAQ)
Q: What does the Lutron BCT-4320SD Benchtop Conductivity Meter measure?
A: The Lutron BCT-4320SD measures Conductivity (uS and mS), TDS (Total Dissolved Solids in PPM), Salt (% by weight), and Temperature (degrees C or F) — all from a single benchtop unit.
Q: Does the BCT-4320SD require special software to read logged data?
A: No. The BCT-4320SD saves all data directly to an SD card in Excel-compatible format. Users remove the SD card, plug it into a computer, and open the file in Microsoft Excel immediately without installing any additional software.
Q: What SD card size does the BCT-4320SD support?
A: The meter accepts SD memory cards with a capacity of 1 GB to 16 GB.
Q: Can users set the sampling interval for the data logger?
A: Yes. In auto mode, users configure the sampling interval from 1 second up to 8 hours 59 minutes 59 seconds. In manual mode, pressing the logger button once saves a single data point at the current moment.
Q: Does the BCT-4320SD compensate for temperature changes automatically?
A: Yes. The meter features Automatic Temperature Compensation (ATC) across 0 degrees C to 60 degrees C. The temperature coefficient is adjustable between 0 and 5.0% per degree C, with a factory default of 2.0% per degree C.
Q: What power source does the BCT-4320SD use?
A: The meter operates on 8 AA (UM-3, 1.5V) batteries or an optional DC 9V adapter. The adapter option suits continuous benchtop operation without the need to replace batteries.
Q: Is the BCT-4320SD suitable for use outside the laboratory?
A: While the BCT-4320SD is primarily a benchtop meter, battery operation allows users to carry it for multi-location field measurements. The manual data logger supports up to 99 position tags for organized multi-point data collection in the field.



Reviews