Description
Introduction Flash and Fire Point Apparatus
Petroleum laboratories across Bangladesh depend on a reliable Flash and Fire Point Apparatus to determine the exact temperature at which fuels and lubricants ignite. This apparatus follows the Cleveland Open Cup method and measures both flash point and fire point in a single test cycle. Refineries use this equipment to verify product safety before distribution, and quality control teams rely on it for consistent, repeatable results.
Specifications Flash and Fire Point Apparatus
| Parameter | Specification |
| Product Name | Flash and Fire Point Apparatus |
| Testing Method | Cleveland Open Cup (COC) |
| Standard Compliance | ASTM D92, IS 1448 (P:69) |
| Temperature Range | Ambient to 400°C |
| Heating Element | Electric heater with controlled ramp rate |
| Heating Rate | Adjustable as per ASTM D92 requirements |
| Test Cup Material | Corrosion-resistant Brass |
| Test Cup Capacity | Standard COC Brass Cup |
| Flame Application | Manual or Automatic Test Flame Applicator |
| Flame Exposer | Precision Timing Mechanism |
| Temperature Sensor | RTD or Thermocouple |
| Display Type | Digital Temperature Display |
| Safety Features | Automatic Heater Cutoff at Flash Detection |
| Calibration | Factory-Calibrated, Field Verification Supported |
| Power Supply | 220V AC, 50Hz, Single Phase |
| Body Construction | Powder-Coated Steel Housing |
| Dimensions | Compact Benchtop Design |
| Application | Flash & Fire Point Testing of Petroleum Products, Lubricants, Bitumen, Fuel Oils, Diesel, and Industrial Oils |
| Optional Accessories | Spare Test Cups, Calibration Certificate, Thermometers |
Key Features Flash and Fire Point Apparatus
- Determines both flash point and fire point in one continuous test
- Follows the Cleveland Open Cup testing method for accurate results
- Heats samples at a controlled, uniform rate for consistent readings
- Includes an automatic test flame applicator for precise ignition detection
- Displays digital temperature readings on a clear control panel
- Suits petroleum, lubricant, and chemical testing laboratories
- Meets international standards trusted by fuel testing facilities worldwide
Applications Flash and Fire Point Apparatus
- Flash point testing of petroleum products and crude oil
- Fire point determination for lubricating oils and greases
- Quality control testing in fuel refineries and blending plants
- Safety compliance testing before fuel transportation and storage
- Research and development of new lubricant formulations
- ASTM D92 and IS 1448 standard compliance testing
- Calibration and comparison testing between testing facilities
Who Uses This Flash and Fire Point Apparatus
- Fuel Refineries – Verify flash point safety limits before releasing products to
- Lubricant Manufacturers – Test oil formulations for fire safety
- Petroleum Testing Laboratories – Perform routine quality checks on incoming fuel
- Government Regulatory Bodies – Confirm fuel products meet national safety
- Power Plants and Industrial Facilities – Monitor lubricant safety for machinery
- Research Institutions – Study thermal and ignition behavior of petroleum-based
Frequently Asked Questions (FAQ) Flash and Fire Point Apparatus
Q1: What does a Flash and Fire Point Apparatus measure?
This apparatus measures the exact temperature at which a petroleum sample’s vapors ignite and continue burning.
Q2: Which testing method does this apparatus follow?
This apparatus follows the Cleveland OpenCup method in accordance with ASTM D92 and IS 1448 standards.
Q3: Can this apparatus test both fuels and lubricants?
Yes, the apparatus tests a wide range of petroleum products, including fuels, lubricating oils, and greases.
Q4: What is the maximum temperature range of this apparatus?
The apparatus heats samples from ambient temperature up to 400°C.
Q5: Does ASTZBD provide calibration certificates?
Yes, we provide calibration certificates with every apparatus upon request.
Q6: What power supply does this apparatus require?
The apparatus operates on a standard 220V, 50Hz single-phase power supply.
Q7: How often should I calibrate this apparatus?
Laboratories typically calibrate the apparatus every six to twelve months, depending on usage frequency and internal quality protocols.
Q8: Does ASTZBD offer installation support?
Yes, our technical team provides installation guidance and operational training upon delivery.
Why Buy From ASTZBD
- ASTZBD sources the Flash and Fire Point Apparatus from certified manufacturers, and this guarantees accurate, standard-compliant performance for every
- Our technical team inspects each apparatus for calibration accuracy before it leaves the warehouse.
- Bangladesh customers receive genuine documentation, prompt delivery, and responsive after-sales support throughout the ownership period.
- ASTZBD maintains competitive pricing without compromising instrument quality or safety compliance. Laboratories across the country choose
- ASTZBD because our technicians provide installation guidance, and our service team responds quickly to calibration and maintenance requests.






Reviews
There are no reviews yet.