Description
Introduction MCP CQ-620A Analog Oscilloscope
The MCP CQ-620A Analog Oscilloscope 20MHz captures and displays dual-channel waveforms for engineers, technicians, and students across Bangladesh. The device projects signals on a 6-inch rectangular CRT screen with an internal graticule of 8 x 10 divisions. Technicians measure voltage swings from 5mV/div to 5V/div and observe rise times as fast as 17.5ns. Instructors also demonstrate CH1, CH2, ALT, CHOP, ADD, and INV modes during lab sessions. ASTZ (Advance Science & Technology Zone) supplies this oscilloscope with genuine MCP components and dedicated after-sales support in Dhaka.
Key Features MCP CQ-620A Analog Oscilloscope
- Displays dual-channel waveforms on a 6-inch rectangular CRT with internal graticule
- Covers a vertical bandwidth of DC to 20MHz and DC to 7MHz in x5 MAG mode
- Switches between CH1, CH2, DUAL (ALT/CHOP), ADD, and CH2 INV vertical modes
- Adjusts sensitivity from 5mV/div to 5V/div, and down to 1mV/div in magnified mode
- Selects trigger sources from CH1, CH2, ALT, LINE, and EXT
- Supports AUTO, NORM, TV-V, and TV-H trigger modes for varied signal types
- Runs X-Y operation with a bandwidth of DC to 500kHz
- Includes a built-in calibrator output of 1kHz square wave at 2Vp-p
SPECIFICATIONS MCP CQ-620A Analog Oscilloscope
| Specification | Details |
|---|---|
| Brand | MCP |
| Model | CQ-620A |
| Bandwidth | 20MHz |
| Country of Origin | China |
| Category | Analog Oscilloscope |
| Feature | Specification |
|---|---|
| CRT Type | 6-inch rectangular CRT with internal graticule |
| Display Grid | 8 × 10 divisions (1 div = 1cm) |
| Accelerating Potential (Z-axis) | 2kV |
| Focus Control | Sensitivity above 5Vp-p |
| Maximum Z-axis Input Voltage | 30V (DC + AC Peak) |
| Z-axis Bandwidth | DC to 2MHz |
| Brightness Control | Positive-going Z-axis input decreases brightness |
| Feature | Specification |
|---|---|
| Frequency Range | 0.1Hz to 1MHz (7 ranges) |
| Output Waveforms | Sine, Square & Triangle |
| Frequency Variable Range | 10:1 or more |
| Output Impedance | 50Ω (±10%) |
| Sine Wave Output | >14Vp-p (Open Circuit), Continuously Adjustable |
| DC Offset | Over 6V (Open Circuit) |
| Sine Wave Distortion | ≤2% (10Hz–100kHz) |
| Square Wave Asymmetry | ≤3% @ 1kHz |
| Rise/Fall Time | ≤120ns @ 50Ω Output |
| Feature | Specification |
|---|---|
| Sensitivity | 5mV/div to 5V/div (±3%) |
| x5 MAG Sensitivity | 1mV/div to 1V/div (±5%) |
| Bandwidth | DC to 20MHz |
| x5 MAG Bandwidth | DC to 7MHz |
| Rise Time | 17.5ns |
| x5 MAG Rise Time | Approx. 50ns |
| Maximum Input Rating | 300V (DC + AC Peak) @ 1kHz |
| Input Coupling | AC / DC / GND |
| Input Impedance | 1MΩ // 25pF |
| Vertical Modes | CH1, CH2, DUAL (ALT/CHOP), ADD, CH2 INV |
| Feature | Specification |
|---|---|
| Sweep Time | 2s/div to 0.5s/div |
| Accuracy | ±3% (±5% with ×10 MAG) |
| Fastest Sweep Rate | 100ns/div |
| Uncalibrated Sweep | 20ns/div & 50ns/div |
| Feature | Specification |
|---|---|
| Trigger Modes | AUTO, NORM, TV-V, TV-H |
| Trigger Sources | CH1, CH2, ALT, LINE, EXT |
| Trigger Slope | Positive (+) / Negative (−) |
| Feature | Specification |
|---|---|
| Sensitivity | 5mV/div to 5V/div (±4%) |
| X-axis Bandwidth | DC to 500kHz |
| Phase Error | ≤3° (DC to 50kHz) |
| Feature | Specification |
|---|---|
| Trigger Output Voltage | Approx. 20mV/div into 50Ω |
| Trigger Output Bandwidth | 50Hz to 5MHz (−3dB) |
| Trigger Output Impedance | Approx. 50Ω |
| Calibrator Output | 1kHz Square Wave, 2Vp-p ±2% |
| Feature | Specification |
|---|---|
| Input Voltage | AC 115/230V ±15% |
| Frequency | 50/60Hz |
| Feature | Specification |
|---|---|
| Dimensions (W × H × D) | 310 × 150 × 455 mm |
| Weight | Approx. 8.5 kg |
Applications
- Electronics labs measure voltage, frequency, and phase across dual channels
- Technicians troubleshoot circuit faults by comparing CH1 and CH2 waveforms
- Instructors demonstrate ALT and CHOP display modes during practical classes
- Engineers test TV video signals using the built-in TV-V and TV-H trigger modes
- Repair centers calibrate other instruments using the onboard calibrator output
- Students study X-Y operation and phase relationships between two signals
Who Uses This
- Electrical and electronics engineering departments
- Polytechnic institutes and technical training centers
- Diploma and vocational electronics students
- TV and appliance repair technicians
- University physics and electronics laboratories
- Private training academies teaching circuit analysis and signal measurement
Frequently Asked Questions
Q1: What is the bandwidth of the MCP CQ-620A Analog Oscilloscope 20MHz? The oscilloscope covers a vertical bandwidth of DC to 20MHz, and DC to 7MHz when a technician engages the x5 magnification mode.
Q2: Does this oscilloscope support dual-channel measurement? The oscilloscope supports dual-channel measurement through CH1, CH2, DUAL (ALT/CHOP), ADD, and CH2 INV vertical modes.
Q3: Which trigger modes does the CQ-620A offer? The oscilloscope offers AUTO, NORM, TV-V, and TV-H trigger modes for general and video signal testing.
Q4: What is the price of the MCP CQ-620A Analog Oscilloscope 20MHz in Bangladesh? ASTZ sells the MCP CQ-620A Analog Oscilloscope 20MHz at ৳49,000, though prices may change based on current stock and offers.
Q5: Does ASTZ provide a warranty for this oscilloscope? ASTZ provides a manufacturer warranty and after-sales technical support for every unit sold.
Q6: Who should use this oscilloscope? Electronics students, repair technicians, and lab instructors use this oscilloscope for waveform analysis and circuit troubleshooting.
Q7: Can this oscilloscope run X-Y operation? The oscilloscope runs X-Y operation with a bandwidth of DC to 500kHz and a phase error of 3° or less up to 50kHz.
Why Buy From ASTZ
- ASTZ supplies genuine MCP oscilloscopes directly to Bangladeshi institutions and technicians.
- The company stocks the MCP CQ-620A Analog Oscilloscope 20MHz in Dhaka and ships orders nationwide.
- Customers receive a manufacturer warranty and dedicated technical support after purchase.
- ASTZ’s team also assists with calibration questions and product setup.
- The store’s physical location at Ittefaq Mor, Dhaka, gives customers the option to inspect the oscilloscope before
- Educational institutions receive customized quotations for bulk orders upon



Reviews
There are no reviews yet.